- Supports 4 door control. It can extend up to 62 DS-K2M002X access modules, and up to 128 doors can be controlled
 - Downstream RS-485 redundancy wiring design to ensure communication stability. 5-ch downlink RS-485 interface supports two applications: 1. When 4-ch RS-485 communication, the 5th RS-485 can be used as a redundant application; 2. 4-ch RS-485 forms 2 groups of dual-bus loops with physical isolation. It is recommended that you do not have more than 16 access modules attached to each loop bus.
 - Web configuration management. All configurations can be realized via web without software application
 - Supports professional access control applications such as multi-door interlocking and anti-passback
 - Supports backup battery access. Charging and discharging are available
 - It has status indicators such as power supply, communication and operation, which is convenient for equipment health detection
 
| 
 System  | 
|
| 
 Operating system  | 
 Linux  | 
| 
 Network  | 
|
| 
 Wired network  | 
 1, 10/100/1000 Mbps self-adaptive  | 
| 
 Interface  | 
|
| 
 Network interface  | 
 1  | 
| 
 Lock control  | 
 4  | 
| 
 Exit button  | 
 4  | 
| 
 Door contact input  | 
 4  | 
| 
 Alarm input  | 
 8  | 
| 
 Alarm output  | 
 4  | 
| 
 TAMPER  | 
 1  | 
| 
 RS-485  | 
 7, 2 for card reader, 5 for access modules (4 for communication, each interface can connect up to 16 access modules; 1 for redundancy)  | 
| 
 Wiegand  | 
 4, standard 26/34 input, supports custom Wiegand settings  | 
| 
 USB  | 
 1, USB 2.0  | 
| 
 Fire interface  | 
 1  | 
| 
 Capacity  | 
|
| 
 User capacity  | 
 100,000  | 
| 
 Fingerprint capacity  | 
 10,000  | 
| 
 Card capacity  | 
 200,000  | 
| 
 Event capacity  | 
 600,000  | 
| 
 Linked door capacity  | 
 Self: 4 doors Extended: up to 128 doors (connected with 62 access modules)  | 
| 
 Linked card reader capaciry  | 
 8 RS-485 card readers (OSDP protocol) and 4 Wiegand card readers  | 
| 
 Authentication  | 
|
| 
 Fingerprint recognition duration  | 
 < 1 s  | 
| 
 General  | 
|
| 
 Indicator  | 
 12 indicators, 1 for indicating power status, 1 for running status, 1 for wired network status, 5 for RS-485 status, and 4 for door status  | 
| 
 Battery  | 
 Charge and discharge  | 
| 
 Power supply  | 
 100 VAC to 240 VAC  | 
| 
 Power consumption  | 
 </= 102 W  | 
| 
 Working temperature  | 
 -10 °C to 55 °C (14 °F to 131 ° F)  | 
| 
 Working humidity  | 
 0% to 90% (No condensing)  | 
| 
 Installation  | 
 Wall mounting  | 
| 
 
 Language  | 
 English, Thai, Traditional Chinese, Indonesian, Vietnamese, Arabic, Spanish (Europe), Spanish (South America), Italian, French, Dutch, Russian, Ukrainian, Portuguese (Europe), Portuguese (Brazil), Serbian, Croatian, Bulgarian, German, Greek, Romanian  | 
| 
 Function  | 
|
| 
 Configuration via Web browser  | 
 Support  | 
| 
 Multi-factor authentication  | 
 Support  | 
| 
 First person in  | 
 Support  | 
| 
 Anti-passback  | 
 Support 32 routes (64 card readers each)  | 
| 
 Multi-door interlocking  | 
 Support 32 groups (32 doors each)  | 