Skip to content

Restaurant Cold-Chain Case Study | Galaxy Security

Case study / Cold-chain monitoring

Milesight IoT · Hospitality & food retail

A warmer cooler.
A missed warning.
A clearer response.

An illustrative cold-chain monitoring case study for a GTA restaurant

Explore the Cold-Chain Package
Restaurant staff checking stock beside an open walk-in cooler.
TemperatureDoor activityWater leaks
Restaurant cold-storage setting · Manufacturer application image; not the case-study site.

During a busy service, a walk-in cooler door is repeatedly opened for preparation and deliveries. After closing, a developing refrigeration problem could go unnoticed until the next scheduled temperature check.

For a restaurant storing high-value seafood and other temperature-sensitive ingredients, the time between a changing condition and a staff response matters.

The operating challenge

The challenge

The restaurant needs visibility across walk-in coolers, freezers and smaller refrigeration units. Paper checks provide useful records at specific moments, but they do not explain everything that happens between inspections.

The monitoring plan must also distinguish temperature changes associated with door activity from conditions that need closer equipment investigation.

Monitoring in practice

The proposed approach

Use Milesight TS302 units with external probes at selected walk-in refrigeration points. Connect magnetic door contacts to record door status alongside temperature readings.

Add EM320-TH sensors at suitable secondary storage locations and WS303 leak sensors near ice machines, dishwashing areas or filtration equipment.

Connect the monitoring devices through a LoRaWAN gateway. Configure temperature thresholds, door-open rules and notification recipients around the restaurant’s operating hours and response responsibilities.

The hardware in context

A device for each monitoring point.

Milesight TS302 LCD unit with manufacturer labels showing temperature, two channels, door status and wireless connectivity.

TS302
Temperature meets door status.

External probes and magnetic contacts connect the refrigeration reading with the door event.

Manufacturer illustration. Display values shown are product examples.

Milesight EM320-TH compact temperature and humidity sensor.
EM320-THTemperature and humidity monitoring at suitable secondary storage locations.
Milesight WS303 compact leak sensor.
WS303Water detection near ice machines, dishwashing areas and filtration equipment.
Milesight UG65 LoRaWAN gateway.
UG65The LoRaWAN connection between monitoring devices and the selected platform.
Walk-in cold-storage monitoring concept A walk-in cooler with an external temperature probe, a door contact and wireless monitoring. TS302 Doorcontact External temperature probe WALK-IN COLD STORAGE
Monitoring concept · Illustrative placement, not an installation drawing.

Placement concept

Connect the reading
to the location.

  • Walk-in refrigeration: external temperature probe at the selected monitoring point.
  • Cooler door: magnetic contact for opening and closing status.
  • Nearby equipment: additional temperature or leak sensing where specified.

The monitoring path

From a recorded condition
to a staff response.

Sense the condition

Temperature probes, door contacts and leak sensors report their selected conditions.

Connect the information

A LoRaWAN gateway carries readings to the configured monitoring platform.

Review and respond

Configured notifications help the appropriate staff investigate an exception.

The intended outcome

What success would look like

A commissioned system would provide usable temperature histories, show relevant door activity and deliver configured exception notifications to the appropriate staff.

TS302 PDF or CSV exports would support record review alongside the restaurant’s HACCP procedures and corrective-action logs.

The business value is clearer information for investigating exceptions and protecting inventory through timely staff action.

Practical answers

Clear answers.
Better project decisions.

Does monitoring make the restaurant HACCP compliant?

Monitoring supports the restaurant’s food-safety programme. Compliance also depends on procedures, calibration, equipment checks and documented corrective actions.

Can staff investigate an overnight temperature rise?

Historical readings and door-status information can help staff review the event. Available records depend on the selected devices, settings and platform.